7. Function list
7-2 SV-iC5
Drive Group
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
CUr [Output
current]
This parameter displays the output current to
the motor.
- - 11-1
rPM [Motor RPM] This parameter displays the number of Motor
RPM.
- - 11-1
dCL [Inverter DC
link voltage]
This parameter displays DC link voltage inside
the inverter.
- - 11-1
This parameter displays the item selected at
H73- [Monitoring item select].
vOL Output voltage
POr Output power
vOL [User display
select]
tOr Torque
vOL - 11-2
nOn [Fault Display] This parameter displays the types of faults,
frequency and operating status at the time of
the fault
- - 11-2
This parameter sets the direction of motor
rotation when drv - [Drive mode] is set to either
0 or 1.
F Forward
drC [Direction of
motor rotation
select]
F/r
r Reverse
F O 9-7