All software images on the stack must be identical to ensure proper operation of the stack. There are two
different ways to update images across the stack:
Image can be updated prior to connecting a unit to the stack. (This is the recommended method.)
Upgrade master and copy master image to units across the stack.
These steps can be done from the Menu-Based CLI or from the web interface.
a. Copy image from TFTP to master
b. Change active image on master
c. Reboot master
d. Copy from master to rest of units
e. Change active of rest of units
f. Reload only rest of units and not master.
NOTE: If there is a backup master in the stack, it takes over as master of the stack following step (c)
above. In such a case steps (a) - (c) should be run on the (old backup) new master unit.
1. Click Admin > File Management > Copy Files. The Copy Files Page opens: