Linksys SFE2000P Switch User Manual


 
233
Chapter 14:
SFE2000/SFE2000P Gigabit Ethernet Switch Reference Guide
Chapter
14
Syslog Server Settings Page
The Syslog Server Settings Page contains the following fields:
Server — Specifies the server to which logs can be sent.
UDP Port (1-65535) — Defines the UDP port to which the server logs are sent. The possible range
is 1 to 65535. The default value is 514.
Facility — Defines a user-defined application from which system logs are sent to the remote server.
Only one facility can be assigned to a single server. If a second facility level is assigned, the first
facility is overridden. All applications defined for a device utilize the same facility on a server. The
field default is Local 7. The possible field values are Local 0 - Local 7.
Description — Provides a user-defined server description.
Severity to Include — Indicates the minimum severity from which logs are sent to the server. For
example, if Notice is selected, all logs from a Notice severity and higher are sent to the remote
server.
3. Define the relevant fields.
4. Click Apply. The Syslog Server settings are modified, and the device is updated.