Chapter 6 Cajun Campus CLI – Layer 2
88 Cajun P332MF User’s Guide
Get time Command
This command retrieves the time from the network.
The syntax for this command is:
get time
Example:
Cajun_P330-N# get time
Time is already being acquired from network!
Note: You must reset the switch after performing the download.
Reset Command
Use the
reset command to restart the system or an individual module. If no
module number is defined or the module number of the Master is defined, the
command resets the entire system. If the module number is defined, the command
resets the specified module only.
The syntax for this command is:
reset [<mod_num>]
Example:
To reset the Master agent and force the entire system to reset:
Cajun_P330-N# reset
This command will force a switch-over to the master module and
disconnect your telnet session.
Do you want to continue (y/n) [n]? y
Connection closed by foreign host.
host%
To reset module 4:
Cajun_P330-N# reset 4
This command will reset module 4 and may disconnect your
telnet session.
Do you want to continue (y/n) [n]? y
Resetting module 4...