Lucent Technologies P332MF Switch User Manual


 
Chapter 6 Cajun Campus CLI Layer 2
Cajun P332MF Users Guide 81
Example:
These examples show how to use the set port flowcontrol command set:
Cajun_P330-N# set flowcontrol receive 1/51 on
Port 1/51 flow control receive administration status set to on
(port will require far end to send flowcontrol)
Cajun_P330-N# set flowcontrol send 1/51 off
Port 1/51 flow control send administration status set to off
(port will send flowcontrol to far end)
Cajun_P330-N# set flowcontrol all 1/17 proprietary
Port 1/17 flow control administration status set to
proprietary
Set auto-negotiation-flowcontrol-advertisement Command
The set auto-negotiation-flowcontrol-advertisement command sets the
flowcontrol advertisement for a Gigabit port when performing autonegotiation.
The syntax for this command is:
set auto-negotiation-flowcontrol-advertisement <mod_num>/
<port_num> {no-flowcontrol|asym-tx-only|sym-only|sym-and-asym-rx}
all Controls the sending and receipt of flow-control frames for any type
of ports:
ON indicates that the local port will both act upon and send
IEEE802.3x flow control frames
OFF indicates that the local port will both discard and not send
flow control frames (of any type)
PROPRIETARY indicates that the local port will both act upon and
send Lucent proprietary flow control frames.
no-flowcontrol The port will advertise no pause capabilities
asym-tx-only The port will advertise asymmetric Tx pause capabilites only
sym-only The port will advertise symmetric pause capabilites only
sym-and-asym-rx The port will advertise both symmetric and asymmetric Rx
pause capabilites