Mitsubishi Electronics LVP-X100A Projector Accessories User Manual


 
50
Indicators / TEMP, LAMP, POWER
The projector has three indicators each of which shows the working condition of the projector.
Though the LAMP and TEMP indicators are on the main menu control window of PCGC, the each
indicator may not match the one of those on the control panel.
INDICATOR
TEMP
INDICATOR
SHOWS
blinking red
CONDITION
Unusual temperature
Normal
Lamp is almost used up.
Lamp is used up.
The power is not turned on.
(Power indicator lights up red.)
Standby
Power-on
Steady green
Steady red
Steady red
Steady green
Blinking red
LAMP
INDICATOR
POWER
INDICATOR
The following offers solutions to possible problems. If a problem persists, turn the projector off
and consult your dealer.
LAMP
SOURCE
FREEZE
/CAPTURE
TEMP
The power is turned off
and the POWER indicator
lights up red.
The ventilation slots or air
filter is clogged with dust
or debris.
The fan has stopped due
to an impediment.
The location temperature
is too high.
The filter is dirty.
POSSIBLE SOLUTIONS
Remove the object from
the ventilation slot.
Pull out the power
plug and remove the
object. If you cannot,
consult your dealer.
Relocate the projector
to a cooler place.
Clean the filter.
-
Replace the lamp.
Exchange with a new
lamp if the same
problem recurs.
-
-