Mitsubishi Electronics SH-080007 Network Card User Manual


 
3 - 27 3 - 27
MELSEC-Q
3 SPECIFICATIONS
Address
Decimal (Hex)
Applicable
protocol
CH1 CH2
Application Name
Initial
value
MC Non Bi
Registration
allowed/not
allowed
Reference
section
8206
(200E
H
)
For designation
of modem
function -3
Circuit disconnect wait time (PLC CPU watch use)
0000
H
to FFFF
H
: Wait time (unit: s)
0
RW
Allowed
Section 8.4.4
Chapter 3 of
User's
Manual
(Application)
8207
(200F
H
)
8456 to
8463
(2108H
to
210FH)
Use prohibited System area
Receive interrupt-issued designation
8208
(2010H)
8464
(2110H)
Interrupt
designation
0: Do not issue interrupt. 1: Issue interrupt.
0 RW Allowed
Chapter 4 of
User's Manual
(Application)
8209
(2011H)
8465
(2111H)
Use prohibited System area
8210
(2012H)
8466
(2112H)
Transmission control start free area designation
64 to 4,095: transmission control start free area
64
8211
(2013H)
8467
(2113H)
Transmission control end free area designation
263 to 4096: transmission control end free area
263
RW
Chapter 7 of
User’s
Manual
(Application)
Non procedure and non reception monitoring time format
designation
8212
(2014H)
8468
(2114H)
For transmission
control
designation (
1)
0: Format-0 1: Format-1
0
RW
Allowed
Chapter 6 of
User’s
Manual
(Application)
8213 to
8215
(2015H
to
2017H)
8469 to
8471
(2115H
to
2117H)
Use prohibited System area
8216
(2018H)
8472
(2118H)
Communication data monitoring designation
0000
H
: No monitor/stopped monitor designation
0001
H
: Monitor start designation
0002
H
: Monitoring (Q series C24 is a set.)
1002
H
: Monitoring stopped (Q series C24 is set.)
100F
H
: Monitor setting error (Q series C24 is a set.)
0
8217
(2019H)
8473
(2119H)
Data optional designation
0: Off 1: On
Full stop designation (b0)
Timer 0 errors at occurrence stop designation (b2)
For system (b1), (b3) to (b15)
0
8218
(201AH)
8474
(211AH)
Monitor buffer head address designation
(400
H
to 1AFD
H
,2600
H
to 3FFD
H
)
CH1:
2600
H
CH2:
3300
H
8219
(201BH)
8475
(211BH)
Communication
data monitoring
function (
1)
Monitor buffer size designation
(0003
H
to 1A00
H
)
0D00
H
RW Allowed
Chapter 16
of User’s
Manual
(Application)
8220 to
8223
(201CH
to
201FH)
8476 to
8479
(211CH
to
211FH)
Use prohibited System area
User frame receive format designation (1st to 4th)
8224 to
8227
(2020
H
to
2023H)
8480 to
8483
(2120
H
to
2123H)
0: Format-0, 1: Format-1
8228 to
8231
(2024H
to
2027H)
8484 to
8487
(2124H
to
2127H)
For designation
of user frame
receiving method
Exclusive format-1 received data count (1st to 4th)
0 or more: Exclusive format-1 received data count
0
RW
Allowed
Section
3.4.7
Chapter 11
of User's
Manual
(Application)
8232 to
8239
(2028H
to
202FH)
8488 to
8495
(2128H
to
212FH)
Use prohibited System area
Transmission transparent code designation (2nd to 4th)
0000
H
Other than 0000
H
:No designation
:Designated (below)
8240 to
8248
(2030
H
to
2038H)
8496 to
8504
(2130
H
to
2138H)
For designation
of transparent
code
• Transparent code (b0 to b7)
00
H
to FF
H
: Transparent code
• Additional code (b8 to b15)
00
H
to FF
H
: Additional code
0
RW Allowed
Section
3.4.5
Chapter 12
of User's
Manual
(Application)
8249 to
8255
(2039
H
to
203FH)
8505 to
8511
(2139
H
to
213FH)
Use prohibited
System area