NETGEAR M4100-D12G Switch User Manual


 
Utility Commands
608
ProSafe M4100 and M7100 Managed Switches
show sflow receivers
Use this command to display configuration information related to the sFlow receivers.
Format show sflow receivers [<index>]
Mode
Example: The following shows example CLI display output for the command.
(switch) #show sflow receivers 1
Receiver Index................................. 1
Owner String...................................
Time out....................................... 0
IP Address:.................................... 0.0.0.0
Address Type................................... 1
Port........................................... 6343
Datagram Version............................... 5
Maximum Datagram Size.......................... 1400
show sflow samplers
Use this command to display the sFlow sampling instances created on the switch.
Format show sflow samplers
Mode
Privileged EXEC
Field Description
Receiver Index
The sFlow Receiver associated with the sampler/poller.
Owner String
The identity string for receiver, the entity making use of this sFlowRcvrTable entry.
Time Out
The time (in seconds) remaining before the receiver is released and stops sending
samples to sFlow receiver.
Max Datagram
Size
The maximum number of bytes that can be sent in a single sFlow datagram.
Port
The destination Layer4 UDP port for sFlow datagrams.
IP Address
The sFlow receiver IP address.
Address Type
The sFlow receiver IP address type. For an IPv4 address, the value is 1 and for an IPv6
address, the value is 2.
Datagram
Version
The sFlow protocol version to be used while sending samples to sFlow receiver.
Privileged EXEC