Nortel Networks 2000 Switch User Manual


 
Mediant 2000 SIP
Mediant 2000 SIP User’s Manual 236 Document #: LTRT-72504
J.4.3 SS7 Signaling Link
Table J-4: SS7 Signaling Link (continues on pages 236 to 237)
ini File Parameter Name Description
SS7_LINK_INDEX
Determines the index field for a line.
The valid range is 0 to 7. The default value is 0.
SS7_LINK_ROWSTATUS
Determines the RowStatus field for a line.
The valid range is acPARAMSET_ROWSTATUS_DOESNOTEXIST to
acPARAMSET_ROWSTATUS_DESTROY. The default value is
acPARAMSET_ROWSTATUS_DOESNOTEXIST.
SS7_LINK_ACTION
Determines the management field for actions.
The valid range is acSS7LINK_PS_ACTION_NONE to
acSS7LINK_PS_ACTION_LPR. The default value is
acSS7LINK_PS_ACTION_NONE.
SS7_LINK_ACTION_RESULT
Determines the management field for actions result.
The valid range is acPARAMSET_ACTION_RESULT_SUCCEEDED to
acPARAMSET_ACTION_RESULT_FAILED. The default value is
acPARAMSET_ACTION_RESULT_SUCCEEDED.
SS7_LINK_NAME
String name for link parameters
The default string is "LINK”.
SS7_LINK_OPERATIONAL_STATE
Determines the operational state of a signaling link.
The valid range is L3_OFFLINE to L3_INSERVICE. The default value is
L3_OFFLINE.
SS7_LINK_ADMINISTRATIVE_STATE
Determines the administrative state of a signaling link.
The valid range is L3_OFFLINE to L3_INSERVICE. The default value is
L3_OFFLINE.
SS7_LINK_TRACE_LEVEL
Determines the trace level of a signaling link (level 2).
The valid range is 0 to 1. The default value is 0.
SS7_LINK_L2_TYPE
Determines the link layer type - defines level 2 media of signaling link.
The valid range is SS7_SUBLINK_L2_TYPE_NONE to
SS7_SUBLINK_L2_TYPE_SAAL. The default value is
SS7_SUBLINK_L2_TYPE_NONE.
SS7_LINK_L3_TYPE
Determines the link high layer type - defines level 3 or L2 high layer of
signaling link.
The valid range is SS7_SUBLINK_L3_TYPE_NONE to
SS7_SUBLINK_L3_TYPE_MTP2_TUNNELING. The default value is
SS7_SUBLINK_L3_TYPE_NONE.
SS7_LINK_TRUNK_NUMBER
Determines the trunk number of a signaling link (TDM).
The valid range is 0 to 7. The default value is 0.
SS7_LINK_TIMESLOT_NUMBER
Determines the time-slot number of a signaling link (TDM).
The valid range is 0 to 31. The default value is 16.
SS7_LINK_MTC_BUSY
Determines the link local busy indicator – if set, indicates link is busy due to
local mtc action.
The valid range is 0 to 1. The default value is 0.
SS7_LINK_INHIBITION
Determines the link inhibit indicator - if set, indicates link is inhibited.
The valid range is 0 to 1. The default value is L3_LINK_UNINHIBITED.
SS7_LINK_LAYER2_VARIANT
Determines the variant (layer 2) of signaling link (TDM).
The valid range is NET_VARIANT_OTHER to NET_VARIANT_CHINA. The
default value is NET_VARIANT_ITU.
SS7_LINK_MTP2_ATTRIBUTES
Determines the MTP2 attributes of signaling link (TDM).
The valid range is 0 to MAX_C7_MTP2_PARAMS_INDEX. The default
value is 3.
SS7_CONGESTION_LOW_MARK
Determines the link congestion low mark of signaling link (TDM).
The valid range is 0 to 255. The default value is 5.
SS7_CONGESTION_HIGH_MARK
Determines the link congestion high mark of signaling link (TDM).
The valid range is 0 to 255. The default value is 20.
SS7_LINK_M2UA_IF_ID
Determines the interface ID (M2UA) of signaling link.
The valid range is 0 to 0xFFFFFFFF. The default value is 0.