Nortel Networks 2000 Switch User Manual


 
Mediant 2000 SIP
Mediant 2000 SIP User’s Manual 68 Document #: LTRT-72504
Click the Close Window button.
7. After modifying the parameters:
To apply the changes to the selected trunk only, click the Apply Trunk Settings button.
To apply the changes to all the trunks, click the Apply to all Trunks button.
The screen is refreshed, parameters become read-only (indicated by being grayed). The
Stop Trunk button appears at the bottom of the screen.
8. To save the changes so they are available after a power fail, refer to Section
5.12 on page
84.
Note: Some parameter configuration options require a device reset; when this is the
case, the Web Interface prompts the user.
9. To reset the Mediant 2000, refer to Section 5.12 on page 84.
5.9.4 Configuring the TDM Bus Settings
To configure the TDM Bus Settings parameters, take these 5 steps:
1. Open the ‘TDM Bus Settings’ screen (Advanced Configuration menu > TDM Bus
Settings); the ‘TDM Bus Settings’ screen is displayed.
2. Configure the TDM Bus Settings parameters.
3. Click the Submit button to save your changes.
4. To save the changes so they are available after a power fail, refer to Section
5.12 on page
84.
5. A device reset is required to activate the TDM Bus Settings parameters. To reset the
Mediant 2000, refer to Section
5.12 on page 84.
Figure
5-18: TDM Bus Settings Screen
Note: Usually the ‘PCM Law Select’ parameter is set to A-law for E1 trunks and to
µ-law for T1 trunks.
Refer to Appendix E on page 205 for information on configuring the ‘TDM Bus Clock Source’,
‘TDM Bus Enable Fallback’ and ‘TDM Bus PSTN Auto Clock’ parameters.