N-Tron 9000 Switch User Manual


 
(Revised 2010-7-2) page 112 of 145
pvid-number
The VLAN-ID number of the VLAN that this port will be a member of
Examples
N-TRON/Admin#[1]> port set pvid 6 2
NOTES
A port can be a member to several VLANs, but can only have one PVID
Set Backpressure
Command Name
port set backpressure
Description
Enables or disables backpressure on a given port. This is normally used on
10Base setups and is a controlled by the hardware.
Syntax
port set backpressure <port-no><enable | disable>
Parameters
port-no
port number (1 ~ 24)
enable | disable
Backpressure enable or disable
Examples
N-TRON/Admin#[1]> port set backpressure 6 enable
NOTES
Check whether port-no is in the valid range. (1 ~ 24)
Set Intruderstate
Command Name
port set intruderstate
Description
Enables or Disables the intruder log.
Syntax
port set intruderstate <enable | disable>
Parameters
enable | disable
Enable or disable the intruder log
Examples
N-TRON/Admin#[1]> port set intruderstate enable
NOTES
This must be enabled for the intruder log to log anything.
Set Priority Level
Command Name
port set prioritylevel
Description
Sets the priority level of a given port.
Syntax
port set prioritylevel <port-no><level>
Parameters
port-no
port number (1 ~ 26)
level
priority level (0 ~ 7)
Examples
N-TRON/Admin#[1]> port set prioritylevel 6 7
NOTES
Priority State should be enabled to use this feature.
Show Configuration
Command Name
port show config
Description
Displays basic configuration settings on given ports.
Syntax
port show config <port-no | all>
Parameters
port-no | all
port number (1 ~ 26), you may enter all to see all the ports at once.
Examples
N-TRON/Admin#[1]> port show config all
NOTES
Check whether port-no is in the valid range. (1 ~ 26)
Show Intruders
Command Name
port show intruder
Description
Displays a list of MAC addresses that were not allowed on the network.
Syntax
port show intruder
Parameters
None
Examples
N-TRON/Admin#[1]> port show intruder
NOTES