104
IP Addresses in FINS Communications Section 5-2
Models Supporting
Automatic Generation
Method (Static)
Models Supporting IP
Address Table Method
Programmable Terminal NS Series No: Set manually so that
automatic settings can be
used with the automatic
generation method.
Open Network Controller (ONC) ---
Product Model/Series/
Version
Supports automatic
generation method
(dynamic)?
Product Model/Series/
Version
Supports automatic
generation method
(static)?
CS-series Ethernet
Unit
100BASE-TX CS1W-ETN21 Yes
10BASE-5 CS1W-ETN01 Yes: Simply called “auto-
matic generation
method.”
10BASE-T CS1W-ETN11
CJ-series Ethernet
Unit
100BASE-TX CJ1W-ETN21 Yes
10BASE-T CJ1W-ETN11 Yes: Simply called “auto-
matic generation
method.”
CV/CVM1-series
Ethernet Unit
10BASE-5 CV500-ETN01
FinsGateway Version 4.xx or
lower
Version 2003 or
higher
Ye s
Programmable Terminal NS Series No: Set manually so that
automatic settings can be
used with the automatic
generation method.
Open Network Controller (ONC) ---
Product Model/Series/
Version
Supports IP address
table method?
CS-series Ethernet
Unit
100BASE-TX CS1W-ETN21 Yes
10BASE-5 CS1W-ETN01
10BASE-T CS1W-ETN11
CJ-series Ethernet
Unit
100BASE-TX CJ1W-ETN21
10BASE-T CJ1W-ETN11
CV/CVM1-series
Ethernet Unit
10BASE-5 CV500-ETN01
FinsGateway Version 4.xx or
lower
Version 2003 or
higher
Programmable Terminal NS Series No: Set manually. FINS
communications are not
possible with personal
computers set automati-
cally by DHCP.
Open Network Controller (ONC) ---