Omron CJ2H-CPU6@-EIP Network Card User Manual


 
399
FINS Commands Addressed to EtherNet/IP Units or Built-in EtherNet/IP Ports Appendix E
Error Code, Detailed Information
Details of the error stored in the record. Refer to 14-4-4 Error Log Error Codes for details.
Minute, Second, Day, Hour, Year, Month
Indicate the time at which the error stored in the record occurred.
Precautions
If the error log contains fewer records than the number specified in the number of records parameter, all
records stored in the error log at the time the command is executed will be returned and the command exe-
cuted will end normally.
Response Codes
ERROR LOG CLEAR
Clears the error log for the EtherNet/IP Unit or built-in EtherNet/IP ports, and resets the number of stored
records to 0.
Command Block
Response Block
Response Codes
PING
Performs processing equivalent to a UNIX computer’s PING command (see below).
Error code Detailed
information
1st byte 10th byte
Minutes Second Day Hour Year Month
Response code Description
0000 Normal end
1001 Command too large
1002 Command too small
1103 Beginning record number is out of range
110C The number of read records is 0.
21 03
Command cod
e
21 03
Response
code
Command
code
Response code Description
0000 Normal end
1001 Command too large