Panasonic PT-VX415NZU Projector User Manual


 
When WEB Control administrator rights password is not set (Non-protect mode)
Connection method
Obtain the IP address and port number (Initial set value = 1 024) of the projector and make a request 1)
for connection to the projector.
Acquire the IP address from the menu screen of the projector, and the port number from the WEB control page. f
IP address :
Obtain from main menu → [NETWORK/USB] → [STATUS]
Port No. :
Acquire from the WEB control → [Detailed set up] → [Port set up] page
There is a response from the projector.2)
Response data r
Data section Blank Mode Termination symbol
Command
example
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘0’
0x30
(CR)
0x0d
Data length
9 bytes 1 byte 1 byte 1 byte
Mode : 0 = Non-protect mode f
Command transmission method
Transmit by the following command format.
Transmitted data r
Header Data section Termination symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length
1 byte 1 byte Undened length 1 byte
Receive data r
Header Data section Termination symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length
1 byte 1 byte Undened length 1 byte
Response data r
String Details Termination symbol
Message
"ERR1" Undened control command
(CR)
0x0d
"ERR2" Out of parameter range
"ERR3" Busy state or no-acceptable period
"ERR4" Timeout or no-acceptable period
"ERR5" Wrong data length
"ERRA" Password mismatch
Data length
4 bytes 1 bytes
ENGLISH
-
125
Chapter 6 Appendix - Technical Information