3-93170-A2-GB20-20 December 1996
To change the customer identification (CID),
1.
Press the
key on the top-level menu to bring
the Ctrl branch onto the front panel LCD.
F1
DS
U E
1 CEPT
Stat Test Cnfig
F2
F3
2. Press F3 to select Ctrl from the top-level menu
screen.
F1
DS
U E
1 CEPT
Test Cnfig Ctrl
F2
F3
3. Press the key on the Control screen until the
CID selection appears on the front panel LCD.
F1
Control:
Rel LED ClrReg
F2
F3
4. Select CID.
F1
Control:
Reset CID DL
F2
F3
5.
Use the
and
keys to position the cursor
under the desired character
. Y
ou must enter a
character before the
moves the cursor to the
next space to the right.
F1
CustID:xxxxxxxx
Up Down Save
F2
F3
6. Enter the desired ID. Press F1 (Up) and F2
(Down) to scroll up and down through the valid
characters/numbers for the customer ID. Valid
characters are 0 through 9, #, -, ., /, A to Z
, and
blank space. Press F3 (Save) to save the ID.
F1
CustID:xxxxxxxx
Up Down Save
F2