Paradyne 317x E1 Network Card User Manual


 
Maintenance
4-213170-A2-GB20-20 December 1996
4.
From the Patterns Send screen, press F1 to send a
511 pattern, F2 to send a 1-in-8 pattern, or F3 to
send a QRSS pattern.
F1
Patterns:
S
end
511 1in8 QRSS
F2
F3
If you send a 1-in-8 pattern, skip Step 5.
5. From the Send screen, press the Function key that
corresponds to the port for which you want to send
a test pattern. Use the scroll keys, if necessary
.
F1
Send:
Name
Prt1 Prt2 Prt3
F2
F3
The T
est Started screen appears.
F1
Send:
Name and Dest
Tes
t S
tarted
F2
F3
If
the E1 DSU/CSU is already sending the test
pattern you selected, the message
Already active
appears. If you selected an incompatible test
pattern combination, the message
Invld T
est
Combo appears. See Table 4-9 for valid
combinations.
Table 4-9
Valid Send Test Pattern Combinations
511 (Port) 1-in-8 (Network) QRSS (Port)
511 (Port) YES (on
separate ports)
NO YES (on
separate ports)
1 in 8 (Network) NO N/A NO
QRSS (Port) YES (on
separate ports)
NO YES (on
separate ports)