Paradyne 8779 Network Router User Manual


 
B. Standards Compliance for SNMP Traps
B-2
May 2002 8700-A2-GB20-40
For a unit defined as an NTU running IP Conservative software, all traps have at a
minimum a variable binding of the Super Overloaded ifIndex (SOI). The formula
for the SOI is:
((LTU Slot Number) * 1,000,000)
+ ((LTU DSL Port Number) * 1,000)
+ the NTUs ifIndex.
warmStart
authenticationFailure
linkUp and linkDown
The link SNMP traps are:
linkUp
The unit recognizes that one of the communication interface is
operational.
linkDown
The unit recognizes that one of the communication interface is not
operational.
The network and synchronous port interfaces (physical sublayer) are represented
by an entry in the MIB-II interfaces table and supported by the DS1 MIB.
SNMP Trap Description Possible Cause
warmStart The unit has reinitialized
itself.
The trap is sent after the unit
resets and stabilizes.
No variable bindings.
Reset command.
Power disruption.
SNMP Trap Description Possible Cause
authenticationFailure Failed attempts to access the
unit.
Variable bindings:
devAuthentication
FailureIPAddress
(Health & Status MIB)
Returns zero if the IP
address is unknown or the
failure came from the
terminal port.
Three unsuccessful attempts
were made to enter a correct
login/password combination.