Paradyne 8779 Network Router User Manual


 
7. Monitoring and Troubleshooting
7-8
May 2002 8700-A2-GB20-40
FPGA Failed The Field Programmable
Gate Array serving all ports
failed.
1. Reset the unit and try again.
2. Call your service
representative for
assistance.
G.703 Failed, Pt 1 The unit failed to loop data on
the G.703 on Port
n
.
Memory
Test
n
Fail
The unit failed memory data
verification (Test 1) or
memory address verification
(Test 2).
Passed No errors were detected. No action is needed.
PLD Failed, Pt
n
An error was detected in a
Programmable Logic Device.
1. Reset the unit and try again.
2. Call your service
representative for
assistance.
TSI CPLD Fail The Complex Programmable
Logic Device serving the
Timeslot Interchanger failed.
TSI Fail The Timeslot Interchanger
failed.
Table 7-2. Self-Test Results Messages (2 of 2)
Message What Message Indicates What To Do