Paradyne 8779 Network Router User Manual


 
B. Standards Compliance for SNMP Traps
B-4
May 2002 8700-A2-GB20-40
Enterprise-Specific Traps
The enterpriseSpecific trap indicates that an enterprise-specific event has
occurred. The Specific-trap field identifies the particular trap that occurred. The
following table lists the enterprise-specific traps supported by the unit:
SNMP Trap Description Possible Cause
enterprisePrimaryClock
Fail(1)
The unit has lost its primary
clock source.
No variable bindings.
Hardware failure in the unit
or the clock source.
enterpriseSelfTestFail(2) A hardware failure of the
unit is detected during the
units self-test. The trap is
generated after the unit
completes initialization.
Variable bindings:
devSelfTestResults
Failure of one or more of the
units hardware components.
enterpriseDeviceFail(3) An internal device failure.
No variable bindings.
Operating software has
detected an internal device
failure.
enterpriseSecondaryClock
Fail(4)
The unit has lost its
secondary clock source.
No variable bindings.
Hardware failure in the unit
or the clock source.
enterpriseTestStart(5) A test is running.
Variable bindings:
devSelfTestResults
ifIndex (RFC 2863)
ifAdminStatus
(RFC 2863)
ifOperStatus (RFC 2863)
ifType (RFC 2863)
ifTestType (RFC 2863)
At least one test has been
started on an interface.
enterpriseConfigChange(6) The configuration changed
via the user interface. The
trap is sent after
60 seconds have elapsed
without another change.
This suppresses the
sending of numerous traps
when multiple changes are
made in a short period of
time, as is typically the case
when changing
configuration options.
No variable bindings.
Configuration has been
changed via the ATI.