6.1.3 MGR Program
System Window
That leaves the MGR system window, which is
part of the MGR program proper. If you have an
external PC connected to the CC1 that contains
the MGR program, there are multiple indications of
online status associated with this program that can
be checked.
Just before the boot process, have the MGR pro-
gram up and running with the system window show-
ing. Click on the SysWindow icon as indicated in
Figure 8; the window should be blank. If it isnt,
close the system window and answer No to the
dialog inquiry about retaining current system win-
dow messages. Then, reopen the window and it
will be blank. At the end of the initialization process
when the Setup Complete message appears on
the diagnostic screen, a corresponding display in-
dicating system status will appear in the system
window of the MGR program, like that shown in
Figure 8, indicating that the system is up and
online.
6.1.4 Configuration File
In addition to the SysWindow message regarding
online status, you can click on the 9760 Setup
icon on the MGR program toolbar, which will bring
up the Configuration Files dialog box (refer to
Figure 9). On the far right side of the line indicat-
ing the Node # and the group configuration file
name associated with that node is another indica-
tion that the system is online. The word Online
appears, as shown in Figure 9. A dash , nor-
mally occupies that spot when the system is not
online.
Figure 8
InitializationSystem Window
Figure 9