Pitney Bowes DM550 Postal Equipment User Manual


 
9 • Maintaining and Updating
9 - 6 SV61436 Rev. D
Cleaning or
Replacing the
Moistener Brush
1. Lift the feed cover.
2. Push down on the moistener brush button.
3. Grasp the moistener brush assembly and pull it straight out towards
you.
4. Clean the moistening brush by running the brush under warm water.
5. If you need to clean or replace the wick, go to Cleaning or Rep
lacing
the Wick procedure below. Otherwise go to step 6.
6. Replace the existing clean moistener brush assembly, or install a new
one
by pushing the assembly back on its track until it snaps into posi-
tion.
7. Check to make sure that the flap blade of the moistener brush assem-
bly is under (and not over) the
stripper finger as shown here.
8. Verify that the moistener brush assembly is perfectly level with the feed
deck.
Moistener brush button
Moistener brush assembly
Flap Blade
Stripper Finger
Feed Deck
Moistener Brush Assembly