Promise Technology M210p Computer Hardware User Manual


 
VTrak M310, M210p Product Manual
216
Enclosure
Enclosure temperature is
above the threshold/
warning threshold
The VTrak is overheating. Check for airflow around
and through the VTrak, and verify that all fans are
working. Replace fans as needed.
Enclosure temperature is
above the critical
threshold
The VTrak is seriously overheating. Check for airflow
around and through the VTrak, and verify that all fans
are working. Replace fans as needed.
Enclosure temperature is
within the normal range
Normal.
Event Log
Event logging is enabled Event logging has been successfully enabled.
Event logging is disabled Event logging has been disabled.
Event log buffer is cleared
in RAM
The event log was cleared.
Event log buffer is cleared
in NVRAM
The non-volatile RAM event log was cleared.
Event log buffer is cleared
in MDD
The MDD (disk drive) event log was cleared.
Host Interface Controller
Host-interface controller
has detected bus reset
The initiator sent a reset command. If this message
appears repeatedly, contact Technical Support. See
page 239.
Host-interface controller
has encountered an
unrecoverable error
Restart the VTrak. See page 169.
Host-interface controller
has received an abort-
task/abort task set/clear
task set command.
Result of user action. Normal.
Host-interface controller
has received an clear
ACA command.
Result of clearing an auto contingent alliance
condition. If this message appears repeatedly,
contact Technical Support. See page 239.
Host-interface controller
has received a LUN reset
command.
Result of user action. Normal.
Event Action