PSC SP400rf Scanner User Manual


 
R44-1027 27
LABEL TRANSMIT
FORMAT CONFIG
LABEL TRANSMIT FORMAT CONFIGURATION ITEMS
(RS-232 AND KEYBOARD WEDGE INTERFACES ONLY)
If you need to send information in addition to label data, the scanner can
be configured to transmit prefixes and/or suffixes as well as symbology
specific identifier characters (Label I.D.).
PREFIX & SUFFIX
If you need to send information in addition to label data, the scanner can
be configured to transmit prefixes and/or suffixes as well as symbology
specific identifier characters. As the examples below show, none, one or
two symbology specific ASCII characters can be added to the beginning of
label in addition to multiple prefix and suffix characters.
NOTE
Using this feature requires a thorough under-
standing of your specific system requirements.
The options available using this feature are:
symbology specific (0 - 2) characters + label data
PP + label data
non-symbology specific characters (1-2) as a prefix + label
data
C
p
C
p
+ label data
label data + non-symbology specific characters (0-2) as a
suffix
label data + C
s
C
s
non-symbology specific characters (1-2) as a prefix + symbol-
ogy specific characters (0-2) + label data
C
p
C
p
+ PP + label data
symbology specific characters (0-2) + label data + non-
symbology specific characters (1-2) as a suffix
PP + label data + C
s
C
s
non-symbology specific characters (1-2) as a prefix + label
data + non-symbology specific characters (1-2) as a suffix
C
p
C
p
+ label data + C
s
C
s