PSC SP400rf Scanner User Manual


 
GENERAL
FEATURES
84
SP400RF
Programming Guide
“WHEN TO BEEP” OPTIONS
The
SP400RF
provides many options for programming the scanner's
audible beep. The beeper may be programmed to be silent
1
, or may be
required to announce one or multiple communication events as they
occur between the scanner, Base Station and host terminal.
NOTE
Before programming this option, ensure that
your selection is compatable with your
scanner's setting for "When to Acknowledge"
on the previous two pages.
Table 1 describes the tone(s), duration and number of repetitions for all
SP400RF beep signals and indicates user programmability of the feature.
Tone — is the frequency of the beep measured in Hertz, with the
lowest tone sounded at 512 Hz and the highest at 4096 Hz.
Lowest
512 Hz
Low
1024 Hz
Medium
2048 Hz
Highest
4096 Hz
Duration — is the time period for which the beep is sounded
measured in milliseconds; 100ms, 250ms, and 500ms increments
are used.
Number of repetitions — is the number of times that the beep is
sounded for that indication.
User Programmable? — indicates whether the beep indication can be
turned OFF/ON using programming labels.
Table 1
Indication Tone (Hz) Duration(ms) # Reps User Progr?
Good Read 1024 100 1 YES
Sent to the Base 2048 100 1 YES
ACK from the Base 4096 100 1 YES
WACK from the Base 4096 100 1 YES
NAK from the Base 512 100 10 YES
Config Upload 4096 100 1 NO
Bad Transmission 512 500 1 NO
SYNC
2
4096 250 1 NO
Bad SYNC
2
512 500 1 NO
Power fail 2048-1024-512 100 3 NO
1 Only the beep indications identified in Table 4-1 as user programmable can be
silenced. The remaining beep indicators are always enabled by default.
2 SYNC occurs when Base Station ID or radio channel selection labels are scanned.