PSC SP400rf Scanner User Manual


 
GENERAL
FEATURES
R44-1027 93
READ VERIFICATION
SP400RF
programming has been improved to allow selection of read
verification "minimum read" requirements by symbology type, rather than
universally. This means that the scanner needn't waste valuable time
verifying high-confidence symbologies, while offering the security of
multiple read verification on less reliable codes.
NOTE
The more times the scanner is required to read and compare the
barcode data, the longer it will take to complete a good read cycle.
To set the minimum read requirement for a desired symbology:
1. Scan the SET label.
2. Scan one symbology label below to select the symbology to
be verified.
3. Scan the label on the following page representing the amount
of times you wish a barcode label of that symbology type to
be read before transmission to the host
4. Repeat steps one through three above until read verification has
been selected for all symbologies you desire to be verified.
5. Scan the END label.
SET -------------------------------------
VERIFY UPC-A---------------
VERIFY UPC-E ---------------
VERIFY EAN-8 ---------------
VERIFY EAN-13--------------
VERIFY INSTORE LABEL ---------
READ VERIFICATION
SYMBOLOGY
TYPE