Q-Logic 2-8C Switch User Manual


 
B – Command Line Interface
Set Config Command
59042-06 A B-37
0
threshold
Initiates a configuration session by which to generate and log alarms for selected
events. The system displays each event, its triggers, and sampling window one
line at a time and prompts you for a value. For each parameter, enter a new value
or press the Enter key to accept the current value shown in brackets. These
parameters must be saved in a configuration and activated before they will take
effect. Refer to the ”Config Command” on page B-10 for information about saving
and activating a configuration. Table B-11 describes the Set Config Threshold
parameters. The switch will down a port if an alarm condition is not cleared within
three consecutive sampling windows (by default 30 seconds). Reset the port to
bring it back online. An alarm is cleared when the threshold monitoring detects
that the error rate has fallen below the falling trigger.
E_D_TOV Error Detect Timeout Value. The
number of milliseconds a port is to wait
for errors to clear. The default is 2000.
PrincipalPriority The priority used in the FC-SW-2
principal switch selection algorithm. 1 is
high, 255 is low. The default is 254.
ConfigDescription Switch configuration description. The
configuration description can be up to
32 characters excluding #, semicolon
(;), and comma (,). The default is
SANbox2-8c FC Switch.
FC-SW-2 Compliant Propagates just the active zone set
throughout the fabric (True, compliant)
or the entire zoning database (False,
non-compliant). The default is True.
LegacyAddressFormat Available only when the FC-SW-2
Compliant parameter is False, this
parameter enables (True) or disables
(False) the use of legacy address
formatting for interoperating with
non-FC-SW-2 switches. Refer to
”FC-SW-2 Compliant” on page B-37.
The default is False.
Table B-10. Set Config Switch Parameters (Continued)
Parameter Description