Q-Logic 2-8C Switch User Manual


 
B – Command Line Interface
Set Config Command
59042-06 A B-39
0
zoning
Initiates an editing session in which to change switch zoning attributes. The
system displays each parameter one line at a time and prompts you for a value.
For each parameter, enter a new value or press the Enter key to accept the
current value shown in brackets.
Table B-12. Set Config Zoning Parameters
Parameter Description
FC-SW-2
AutoSave
Available only when the FC-SW-2 Compliant parameter is
True, this parameter enables (True) or disables (False) the
saving of changes to active zone set in the switch’s permanent
memory. Refer to ”FC-SW-2 Compliant” on page B-37. The
default is True.
Disabling the Autosave parameter can be useful to prevent the
propagation of zoning information when experimenting with
different zoning schemes. However, leaving the Autosave
parameter disabled can disrupt device configurations should a
switch have to be reset. For this reason, the Autosave
parameter should be enabled in a production environment.
Default Visibility Enables (All) or disables (None) communication among the
switch’s ports/devices and the fabric in the absence of an
active zone set. The default is All.