[1]: Specify the set value for the timer RB I/O control register.
[2]: Specify the set value for the timer RB prescaler register.
[3]: Specify the set value for the timer RB primary register.
[4]: Specify the set value for the timer RB secondary register.
[5]: Specify the set value for the timer RB mode register.
[6]: Specify the set value for the timer RB control register.
• When using timer RD (RAPI_TIMER_RD0 to RAPI_TIMER_RD1)
[0]: Specify the set value for the timer RD mode register.
[1]: Specify the set value for the timer RD PWM mode register.
[2]: Specify the set value for the timer RD function control register.
[3]: Specify the set value for the timer RD general register Ai (i=0,1).
[4]: Specify the set value for the timer RD general register Bi (i=0,1).
[5]: Specify the set value for the timer RD general register Ci (i=0,1).
[6]: Specify the set value for the timer RD general register Di (i=0,1).
[7]: Specify the set value for the timer RD digital filter function select register
i(i=0,1).
[8]: Specify the set value for the timer RD control register i(i=0,1).
[9]: Specify the set value for the timer RD I/O control register Ai(i=0,1).
[10]: Specify the set value for the timer RD I/O control register Ci(i=0,1).
[11]: Specify the set value for the timer RD status register i(i=0,1).
[12]: Specify the set value for the timer RD interrupt enable register i(i=0,1).
[13]: Specify the set value for the timer RD counter i(i=0,1).
[14]: Specify the set value for the timer RD start register.
[15]: Specify the set value for the timer RD output master enable register 1.
[16]: Specify the set value for the timer RD output master enable register 2.
[17]: Specify the set value for the timer RD output control register.
• When using timer RE (RAPI_TIMER_RE)
[0]: Specify the set value for the timer RE second data register.
[1]: Specify the set value for the timer RE minute data register.
[2]: Specify the set value for the timer RE hour data register.
[3]: Specify the set value for the timer RE day of week data register.
[4]: Specify the set value for the timer RE control register 2.
[5]: Specify the set value for the timer RE count source select register.
[6]: Specify the set value for the timer RE control register 1.
(H8/300H)
• When using timer A (RAPI_TIMER_A specified)
[0]: Specify the set value for timer mode register A.
[1]: Specify the set value for timer counter A.
• When using timer B1 (RAPI_TIMER_B1 specified)
[0]: Specify the set value for timer mode register B1.
[1]: Specify the set value for timer load register B1.
• When using timer V (RAPI_TIMER_V specified)
[0]: Specify the set value for timer counter V.
[1]: Specify the set value for time constant register A.