RAPI_AN4 Uses AN4 pin for the analog input pin.
RAPI_AN5 Uses AN5 pin for the analog input pin.
RAPI_AN6 Uses AN6 pin for the analog input pin.
RAPI_AN7 Uses AN7 pin for the analog input pin.
RAPI_AN8 Uses AN8 pin for the analog input pin.
RAPI_AN9 Uses AN9 pin for the analog input pin.
RAPI_AN10 Uses AN10 pin for the analog input pin.
RAPI_AN11 Uses AN11 pin for the analog input pin.
RAPI_AN12 Uses AN12 pin for the analog input pin.
RAPI_AN13 Uses AN13 pin for the analog input pin.
RAPI_AN14 Uses AN14 pin for the analog input pin.
RAPI_AN15 Uses AN15 pin for the analog input pin.
RAPI_AN0_GROUP
Uses AN0–AN3 group for the analog input pin.
RAPI_AN4_GROUP
Uses AN4–AN7 group for the analog input pin.
RAPI_AN8_GROUP
Uses AN8–AN11 group for the analog input pin.
RAPI_AN12_GROUP
Uses AN12–AN15 group for the analog input pin.
RAPI_134_STATES Conversion time = 134 states
RAPI_70_STATES Conversion time = 70 states
RAPI_AD_ON Sets the AD converter to start operating in __CreateAD.
RAPI_AD_OFF Sets the AD converter to stop operating in __CreateAD.
RAPI_RISING_TRIGGER Includes a rising-edge external trigger in the A/D conversion
start condition.
RAPI_FALLING_TRIGGER Includes a falling-edge external trigger in the A/D conversion
start condition.
RAPI_AD_INT_REQUEST Requests assertion of interrupt for A/D conversion interrupt.
RAPI_NOT_AD_INT_
REQUEST
Does not request assertion of interrupt for A/D conversion
interrupt.
• Specifiable definition values when one-shot mode is used (RAPI_ONE_SHOT specified)
(Input pin)
Specify one from { RAPI_AN0, RAPI_AN1, RAPI_AN2, RAPI_AN3, RAPI_AN4,
RAPI_AN5, RAPI_AN6, RAPI_AN7, RAPI_AN8, RAPI_AN9, RAPI_AN10,
RAPI_AN11, RAPI_AN12, RAPI_AN13, RAPI_AN14, RAPI_AN15 }. The default
value is RAPI_AN0.
(Conversion
time)
Specify one from { RAPI_134_STATES, RAPI_70_STATES }. The default
value is RAPI_134_STATES.
(Operating
states set)
Specify one from { RAPI_AD_ON, RAPI_AD_OFF }. The default value is
RAPI_AD_OFF.
(Trigger) Specify one from { RAPI_RISING_TRIGGER, RAPI_FALLING_TRIGGER }.
If no triggers are specified, “Trigger input disabled” is set.
(Interrupt
request)
Specify one from { RAPI_AD_INT_REQUEST,
RAPI_NOT_AD_INT_REQUEST }.
The default value is RAPI_NOT_AD_INT_REQUEST.
• Specifiable definition values when repeat mode is used (RAPI_REPEAT specified)