Renesas RJJ10J1643-0101 Network Card User Manual


 
Rev.1.01 2007.02.16
RJJ10J1643-0101
141
[3]: Specify the set value for timer control register V0.
[4]: Specify the set value for timer control register V1.
[5]: Specify the set value for timer control/status register V.
• When using timer W (RAPI_TIMER_W specified)
[0]: Specify the set value for timer control register W.
[1]: Specify the set value for timer interrupt enable register W.
[2]: Specify the set value for timer status register W.
[3]: Specify the set value for timer I/O control register 0.
[4]: Specify the set value for timer I/O control register 1.
[5]: Specify the set value for the timer counter.
[6]: Specify the set value for general register A.
[7]: Specify the set value for general register B.
[8]: Specify the set value for general register C.
[9]: Specify the set value for general register D.
[10]: Specify the set value for the timer mode register W.
• When using timer Z (RAPI_TIMER_Z0 to RAPI_TIMER_Z1 specified)
[0]: Specify the set value for the timer mode register.
[1]: Specify the set value for the timer PWM mode register.
[2]: Specify the set value for the timer function control register.
[3]: Specify the set value for the timer output master enable register.
[4]: Specify the set value for the timer output control register.
[5]: Specify the set value for the timer counter.
[6]: Specify the set value for general register A i(i=0,1).
[7]: Specify the set value for general register B i(i=0,1).
[8]: Specify the set value for general register C i(i=0,1).
[9]: Specify the set value for general register D i(i=0,1).
[10]: Specify the set value for timer control register_i (i = 0, 1).
[11]: Specify the set value for timer I/O control register A_i (i = 0, 1).
[12]: Specify the set value for timer I/O control register C_i (i = 0, 1).
[13]: Specify the set value for timer status register_i (i = 0, 1).
[14]: Specify the set value for timer interrupt enable register_i (i = 0, 1).
[15]: Specify the set value for PWM mode output level control register_i (i = 0, 1).
[16]: Specify the set value for the timer start register.
• When using timer RC (RAPI_TIMER_RC)
[0]: Specify the set value for timer RC control register 1.
[1]: Specify the set value for timer RC control register 2.
[2]: Specify the set value for timer RC interrupt enable register.
[3]: Specify the set value for timer RC status register.
[4]: Specify the set value for timer RC I/O control register 0.
[5]: Specify the set value for timer RC I/O control register 1.
[6]: Specify the set value for timer RC output enable register.
[7]: Specify the set value for timer RC digital filter function select register.
[8]: Specify the set value for timer RC counter.
[9]: Specify the set value for general register A.
[10]: Specify the set value for general register B.