(Interrupt) If overflow interrupt requests are enabled, specify RAPI_OVERFLOW. If
no interrupts are specified, “No interrupt request” is set.
(Input pin) Specify one from { RAPI_FTIOA, RAPI_FTIOB }. The default value is
RAPI_FTIOA.
(Clock for digital
filter)
Specify one from { RAPI_TRC_FILTER_F1, RAPI_TRC_FILTER_F8,
RAPI_TRC_FILTER_F32, RAPI_TRC_FILTER_F }. The default value is
RAPI_TRC_FILTER_F32.
[data2]
(M16C) (R8C)
Specify the interrupt priority level (07) to be set in the interrupt control register.
(H8/300H)
Specify the interrupt priority level (0–1) to be set in the interrupt control register. For
the CPUs that do not have an interrupt control register, specify 0.
[data3]
(M16C) (H8/300H)
Specify 0.
(R8C)
When using timer X, specify the set value for the timer register.
[data4]
(M16C) (H8/300H)
Specify 0.
(R8C)
Specify the set value for the prescaler register.
Return value
If the timer specification is incorrect, RAPI_FALSE is returned; otherwise, RAPI_TRUE is
returned.
Functionality
Timer (pulse period measurement mode)
Reference
__EnablePulsePeriodMeasurementMode, __DestroyPulsePeriodMeasurementMode,
__GetPulsePeriodMeasurementMode
Remark
If an undefined value is specified in the first argument, operation of the API cannot be
guaranteed.
The specifiable timers differ with each CPU used.
When used for the H8/300H, this API specify when freeing it from module stanby
state.
Program example
#include "rapi_timer_r8c_13.h"
void TimerIntFunc( void ){}
void func( void )
{
/* Set up timer X as pulse period measurement mode */
__CreatePulsePeriodMeasurementMode(
RAPI_TIMER_X|RAPI_TIMER_ON|RAPI_FALLING_FALLING|RAPI_F8,
5, 0x80, 0x80, TimerIntFunc);
}