Rev.1.01 2007.02.16
RJJ10J1643-0101
189
(Input pin)
Specify one from { RAPI_AN0, RAPI_AN1, RAPI_AN2, RAPI_AN3, RAPI_AN4,
RAPI_AN5, RAPI_AN6, RAPI_AN7, RAPI_AN8, RAPI_AN9, RAPI_AN10,
RAPI_AN11, RAPI_AN12, RAPI_AN13, RAPI_AN14, RAPI_AN15 } The default
value is RAPI_AN0.
(Conversion
time)
Specify one from { RAPI_134_STATES, RAPI_70_STATES }. The default
value is RAPI_134_STATES.
(Operating
states set)
Specify one from { RAPI_AD_ON, RAPI_AD_OFF }. The default value is
RAPI_AD_OFF.
(Trigger) Specify one from { RAPI_RISING_TRIGGER, RAPI_FALLING_TRIGGER }.
If no triggers are specified, “Trigger input disabled” is set.
• Specifiable definition values when single sweep mode is used
(RAPI_SINGLE_SWEEP specified)
(Input pin) Specify one from { RAPI_AN0_GROUP, RAPI_AN4_GROUP,
RAPI_AN8_GROUP, RAPI_AN12_GROUP }.
The default value is RAPI_AN0_GROUP.
(Conversion
time)
Specify one from { RAPI_134_STATES, RAPI_70_STATES }. The default
value is RAPI_134_STATES.
(Operating
states set)
Specify one from { RAPI_AD_ON, RAPI_AD_OFF }. The default value is
RAPI_AD_OFF.
(Trigger) Specify one from { RAPI_RISING_TRIGGER, RAPI_FALLING_TRIGGER }.
If no triggers are specified, “Trigger input disabled” is set.
(Interrupt
request)
Specify one from { RAPI_AD_INT_REQUEST,
RAPI_NOT_AD_INT_REQUEST }.
The default value is RAPI_NOT_AD_INT_REQUEST.
• Specifiable definition values when repeat sweep mode 0 is used
(RAPI_REPEAT_SWEEP0 specified)
(Input pin) Specify one from { RAPI_AN0_GROUP, RAPI_AN4_GROUP,
RAPI_AN8_GROUP, RAPI_AN12_GROUP }. The default value is
RAPI_AN0_GROUP.
(Conversion
time)
Specify one from { RAPI_134_STATES, RAPI_70_STATES }. The default
value is RAPI_134_STATES.
(Operating
states set)
Specify one from { RAPI_AD_ON, RAPI_AD_OFF }. The default value is
RAPI_AD_OFF.
(Trigger) Specify one from { RAPI_RISING_TRIGGER, RAPI_FALLING_TRIGGER }.
If no triggers are specified, “Trigger input disabled” is set.
[data2]
(M16C)
The set value differs with the A/D conversion mode used.
One-shot mode Specify 1.
Repeat mode
Single sweep mode Specify 2, 4, 6, or 8.
Repeat sweep mode 0
Simultaneous sampling mode
Delayed trigger mode 0