Renesas RJJ10J1643-0101 Network Card User Manual


 
Rev.1.01 2007.02.16
RJJ10J1643-0101
57
RAPI_TB1_F256 Timer B1 counts with internal clock φ/256.
RAPI_TB1_F512 Timer B1 counts with internal clock φ/512.
RAPI_TB1_F2048 Timer B1 counts with internal clock φ/2048.
RAPI_TB1_F8192 Timer B1 counts with internal clock φ/8192.
RAPI_TV_F4 Timer V counts on falling edges of internal clock φ/4.
RAPI_TV_F8 Timer V counts on falling edges of internal clock φ/8.
RAPI_TV_F16 Timer V counts on falling edges of internal clock φ/16.
RAPI_TV_F32 Timer V counts on falling edges of internal clock φ/32.
RAPI_TV_F64 Timer V counts on falling edges of internal clock φ/64.
RAPI_TV_F128 Timer V counts on falling edges of internal clock φ/128.
RAPI_TIMER_ON Sets the timer to start operating in __CreateTimer.
RAPI_TIMER_OFF Sets the timer to stop operating in __CreateTimer.
RAPI_OVERFLOW Enables overflow interrupt.
RAPI_OUT_F4 Outputs φ/4 clock.
RAPI_OUT_F8 Outputs φ/8 clock.
RAPI_OUT_F16 Outputs φ/16 clock.
RAPI_OUT_F32 Outputs φ/32 clock.
RAPI_OUT_8192 Outputs φW/4 clock.
RAPI_OUT_4096 Outputs φW/8 clock.
RAPI_OUT_2048 Outputs φW/16 clock.
RAPI_OUT_1024 Outputs φW/32 clock.
RAPI_AUTO_RELOAD Uses auto reload facility.
• Specifiable definition values when timer A is used (RAPI_TIMER_A specified)
(Clock) Specify one from { RAPI_TA_F8, RAPI_TA_F32, RAPI_TA_F128,
RAPI_TA_F256, RAPI_TA_F512, RAPI_TA_F2048, RAPI_TA_F4096,
RAPI_TA_F8192 }.
The default value is RAPI_TA_F8192.
(Interrupt) If overflow interrupt requests are enabled, specify RAPI_OVERFLOW. If
no interrupts are specified, “No interrupt request” is set.
(Output) Specify one from { RAPI_OUT_F4, RAPI_OUT_F8, RAPI_OUT_F16,
RAPI_OUT_F32, RAPI_OUT_8192, RAPI_OUT_4096,
RAPI_OUT_2048, RAPI_OUT_1024 }. If this specification is omitted,
“Clock output” is set.
• Specifiable definition values when timer B1 is used (RAPI_TIMER_B1 specified)
(Clock) Specify one from { RAPI_TB1_F4, RAPI_TB1_F16, RAPI_TB1_F64,
RAPI_TB1_F256, RAPI_TB1_F512, RAPI_TB1_F2048,
RAPI_TB1_F8192 }. The default value is RAPI_TB1_F8192.
(Interrupt) If overflow interrupt requests are enabled, specify RAPI_OVERFLOW. If
no interrupts are specified, “No interrupt request” is set.
(Reload) To select the auto reload facility, specify RAPI_AUTO_RELOAD. If
RAPI_AUTO_RELOAD is not specified, “Select interval facility” is set.
• Specifiable definition values when timer V is used (RAPI_TIMER_V specified)
(Clock) Specify one from { RAPI_TV_F4, RAPI_TV_F8, RAPI_TV_F16,
RAPI_TV_F32, RAPI_TV_F64, RAPI_TV_F128}. If this specification is