__DestroyPulsePeriodMeasurementMode
Synopsis
<Discard settings of pulse period measurement mode>
Boolean __DestroyPulsePeriodMeasurementMode(unsigned long data)
data Setup data (content differs with MCU type)
Description
Discards settings of the timer that is set to specified pulse period measurement mode.
[data]
For data, the following definition values can be set.
(M16C)
RAPI_TIMER_B0 Selects timer B channel 0.
RAPI_TIMER_B1 Selects timer B channel 1.
RAPI_TIMER_B2 Selects timer B channel 2.
(R8C)
RAPI_TIMER_X Selects timer X.
RAPI_TIMER_RA Selects timer RA.
(H8/300H)
RAPI_TIMER_W Selects timer W.
RAPI_TIMER_Z0 Selects timer Z channel 0.
RAPI_TIMER_Z1 Selects timer Z channel 1.
RAPI_TIMER_RC Selects timer RC.
RAPI_TIMER_RD
0
Selects timer RD channel 0.
RAPI_TIMER_RD
1
Selects timer RD channel 1.
RAPI_TIMER_RD
2
Selects timer RD channel 2.
RAPI_TIMER_RD
3
Selects timer RD channel 3.
Return value
If the timer specification is incorrect, RAPI_FALSE is returned; otherwise, RAPI_TRUE
is returned.
Functionality
Timer (pulse period measurement mode)
Reference
__CreatePulsePeriodMeasurementMode, __EnablePulsePeriodMeasurementMode,
__GetPulsePeriodMeasurementMode
Remark
If an undefined value is specified in the argument, operation of the API cannot be
guaranteed.
The specifiable timers differ with each CPU used.