Key Operator Settings
58
6
User Parameters
The User Parameters allow you to customize various settings to match your
needs.
To change the function settings, set the user parameter switches.
Preparation
Access to some User Parameter Settings requires installation of optional
equipment or that other settings be made beforehand.
❖
❖❖
❖ Switches and Bits
User Parameters are divided into switches and each switch is divided into
eight bits. The right most bit is bit 0 and the left most is bit 7.
The User Parameter switches are outlined below.
Bit
Number
76543210
Bit Value
↓↓↓↓↓↓↓↓
01000000
Switch Bit Item 1 0
00 3,2,1 Image density adjustment level home position (the higher level,
the greater image density)
000: Standard,
001: lighter,
010: darker
101: somewhat lighter
110: somewhat darker
5,4 5, 4: Default resolution when you send a message.
RESOLUTION
00: Standard
01: Detail
10: Fine
6 Default setting for trans-
mission.
TRANSMISSION MODE
Immediate Memory
7 Home position for the
Original Type.
HALFTONE
Photo Text
01 7 Return the machine to the
default settings after each
communication (
Return
to default after
transmission
)
On Off