SEAL 6500 Laminator User Manual


 
FRONT CONTROL PANEL
12
1. Air Pressure Gauge: Indicates the PSI reading for the
downward pressure of the top main roller. The standard
setting for the normal operation is 35-55 PSI.
2. Air Regulator Knob: Adjusts the downward pressure of
the top roller. Turn clockwise to increase the pressure.
3. Roller Up/Down Switch (Front, Top): Press up to raise
the roller. Press down to lower the roller.
4. Cooling Fan On/Off Button: Turns On/Off the cool-
ing fan. The corresponding LED will be lit when the fan
is ON.
5. Reset Button: Press this button to reset the material
total usage counter to zero. Totalizer Display must be
showing to be able to zero out.
6. Ratemeter/Totalizer Button: Pressing this button will
toggle between the roller speed readout or total material
usage. Press this button to track and display the total
number of feet or meters run in a given period, which can
help to monitor film usage. The total will be stored even
after the laminator is turned off and adds to the total
whenever the bottom main roller is turning. The corre-
sponding LED will be lit when the totalizer is being used.
7. Ratemeter/Totalizer Readout: Displays the rate of
speed of the main rollers in either feet or meters per
minute, or displays the total number of feet or meters run
in a given period.
8. Top Roller Temperature Increase Button: Press this
button once to view the temperature set point. Press and
hold the button to raise the top roller temperature.
9. Top Roller Temperature Readout: Displays both the
set and actual temperature of the top roller.
10. Top Roller Temperature Decrease Button: Press this
button once to view the temperature set point. Press and
hold the button to lower the top roller temperature.
11. Bottom Roller Temperature Increase Button: Press
this button once to view the temperature set point. Press
and hold the button to raise the bottom roller tempera-
ture.
12. Bottom Roller Temperature Readout: Displays both
the set and actual temperature of the bottom roller.
13. Bottom Roller Temperature Decrease Button: Press
this button once to view the temperature set point. Press
and hold the button to lower the bottom roller tempera-
ture.
14. Bottom Roller Temperature On/Off Button: Turns
On/Off the bottom roller heater. The corresponding LED
will be lit when the heater is ON.
15. Top Roller Temperature On/Off Button: Turns
On/Off the top roller heater. The corresponding LED will
be lit when the heater is ON.
16. Stand-By On/Off Switch: Press this switch up to turn
on the laminator. Press this switch down to put it on
Standby. In Standby, the laminator power is still on, but
all functions are disabled.
Figure 5. Front Control Panel