Chapter 5. Setting Up the Ethernet
May 2002 T-38324-A Page 5-13
d. Click on the drop-down menu next to 3964R Baud Rate to change the baud rate
used for communications to and from the barcode scanner attached to the RS-422
port.
You can select from the following baud rates:
• 1200 • 19200
• 2400 • 38400
• 4800 • 57600
• 9600
e. Click on 3964R Byte Timeout (ms) and enter the timeout in milliseconds for the
barcode scanner attached to the RS-422 port.
7. To save your changes, click OK.
The new settings are flashed to the Ethernet interface card.
NOTE: To flash the new application settings to the Ethernet interface
card, make sure you click
OK
before
Cancel
. If you do not click
OK
first, the changes are not flashed to the Ethernet interface
card.
8. To exit the Application Settings window, click Cancel.
Setting Up Visual Supervisor for an Ethernet Network
Install Visual Supervisor on the computer that will be permanently attached to the Ethernet network.
During installation of Visual Supervisor on the computer, the installation program will give you the
choice to install Visual Supervisor in permanent or portable mode. You must select permanent mode.
To find out how to install Visual Supervisor in more detail, refer to the Visual Supervisor User’s
Guide (part number 39-30-34823).