Sun Microsystems V40Z Server User Manual


 
112 Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide May, 2004
Diags Run Tests Subcommand
Description: Submits one or more diagnostic tests for execution.
Format
Command format:
diags run tests [ [{ -n | --name} TEST NAME ] [{-a| --all}]
[-H | --noheader] [-P | --noprogress] [{-m | --module} MODULE NAME]
[-v | --verbose]
TABLE C-7 lists the arguments for this subcommand.
The following data displays after a test is run:
Submitted Test Name
Test Handle
NWSE_InvalidArgument 4 One or more arguments were incorrect or invalid.
NWSE_NoPermission 6 Not authorized to perform this operation.
NWSE_MissingArgument 7 Missing argument(s).
TABLE C-7 Arguments for Subcommand diags run tests
Arguments Description
{ -n | --name} Specifies the specific test(s) to execute. Run diags get tests
for a list of individual test names.
{-a | --all} Specifies that all tests are to be executed. Run diags get
tests for a list of all available tests. Specifying no arguments
also runs all tests for each device in the server.
{-H |--noheader} Suppresses header output.
{-P | --noprogress} Suppresses progress dots when waiting for test results.
{-m | --module} Specifies that only tests for the specified module are to be
executed. Run diags get tests for a list of modules.
[-v | --verbose] If specified, the Test Details display following the test result
line.
TABLE C-6 Return Codes for Subcommand diags get tests
Return Code ID Description