224 Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004
SP Update Flash Applications Subcommand
Description: The SP file system is divided into two componenets: Base and
Value-Add. The Base component includes the repository and the Value-Add
component includes the application software.
This command copies the file Value-Add to the Value-Add component of the SP
flash. The new Value-Add image takes effect after you reset the SP.
Format
Command format:
sp update flash applications {-f | --filename}
TABLE H-94 lists the arguments for this subcommand.
Return Codes
TABLE H-95 lists the return codes for this subcommand.
TABLE H-94 Arguments for Subcommand sp update flash applications
Argument Description
{-f | --filename} Specifies the full path of the file.
TABLE H-95 Return Codes for Subcommand sp update flash applications
Return Code ID Description
NWSE_Success 0 Command successfully completed.
NWSE_InvalidUsage 1 Invalid usage: bad parameter usage, conflicting
options specified.
NWSE_NotFound 5 Entity (user, service, file, path or other) was not
found.
NWSE_NoPermission 6 Not authorized to perform this operation.
NWSE_NoMemory 8 Insufficient memory.
NWSE_FileError 18 File open, file missing, or a read or write error
occurred.
NWSE_DeviceError 25 Unable to read or write to the device.