Sun Microsystems V40Z Server User Manual


 
148 Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide May, 2004
Return Codes
TABLE F-19 lists the return codes for this subcommand.
Platform Set Power State Subcommand
Description: Provides the ability to turn the platform power on or off from within a
script. However, there are equivalent, less-destructive commands available. This
command does not notify the platform OS of the request through the supplied
channels.
Format
Command format:
platform set power state [{-W|--nowait}] [{-f|--forced}]
[{-t|--timeout} TIME] {off|on|cycle}
TABLE F-19 Return codes for Subcommand platform get power state
Return Code ID Description
NWSE_Success 0 Command successfully completed.
NWSE_InvalidUsage 1 Invalid usage: bad parameter usage, conflicting options
specified.
NWSE_RPCTimeout 2 Request was issued, but was not serviced by the server.
RPC procedure timed out and the request may or may
not have been serviced by the server.
NWSE_RPCNotConnected 3 Unable to connect to the RPC server.
NWSE_NoPermission 6 Not authorized to perform this operation.