Section 4: Maintenance
013-100149-02 Rev. 1 (01/07) Christie DS+60/DW30/Matrix 3000 User’s Manual 4-7
Figure 4.4.
6. Discard the lamp using approved disposal methods for your area. NOTE: Lamps
containing mercury must be treated as hazardous waste if discarded in large
volumes.
WARNING
Do not stick hands into an empty lamp compartment,
especially if the other lamp is still on. The lamp
compartment can become quite hot and cause physical
injury.
7. On the new lamp module, turn the
three lock screws to the “unlock”
position before inserting it into the
lamp compartment. Align the lamp
with the three pins located at the
back of the compartment. Insert the
lamp all the way in until it is fully
seated. (Figure 4.5)
8. Turn the three lock screws on the
new lamp module clockwise a
quarter turn to “lock” it in place.
(See Figure 4.4 for lock screw
position.)
9. Close the lamp door and tighten the
screw to secure it in place.
NOTE: The projector automatically
detects a new lamp and records the
serial number in software the next time
it’s powered up. Manual entry of the serial number is not required.
Figure 4.5.