Texas Instruments DW30 Projector User Manual


 
Section 3: Operation
3-24 Christie DS+60/DW30/Matrix 3000 User’s Manual 013-100149-02 Rev. 1 (01/07)
PLUG & DISPLAY (EDID): By default, a Plug & Play
(EDID) source outputs a signal according to the EDID
information provided by the projector. To override this
information and display in a different format (for example,
if your Plug & Play [EDID] device does not support the
projector’s resolution and/or frequency), select the desired
Plug & Play (EDID) resolution from the list.
Any daisy-chained projectors will also display according
to the chosen Plug & Play (EDID) format.
EDID = Extended Display Identification Data standard.
Figure 3. 13 Blanking of a PIP Image
Use options in the Image
Settings menu to alter your
image without affecting its
size or position. Changes
made to the Image Settings
menu are applied immediately
and are saved when you exit
the menu (press
Exit
or
Menu
)
.
Options not available for the
projector model or source are
disabled and appear dim
(gray).
Contrast
(
SHORT CUT: Press
Contrast
and adjust the slidebar.)
“Contrast” increases or decreases the perceived difference between light and dark
areas of your image (0-100). For best results, keep close to 50. If contrast is set too
high, the light parts of the image lose detail and clarity. If set too low, the light areas
will not be as bright as they could be and the overall image will be dim. For best
results, start with a low value and increase so that whites remain bright but are not
distorted or tinted, and that light areas do not become white (i.e., are “crushed”).
NOTE: If the environment lighting changes, an adjustment of Gamma is
recommended (see below).
Ima
g
e Settin
g
s Menu f