Tripp Lite SU120KX2 Power Supply User Manual


 
1
5
9
3
7
11
2
6
10
4
8
12
13
14
2
Table of Contents
1 Introduction 3
2 Important Safety Instructions 4
3 Control Panel Features 6
4 Front and Rear Panel Features 7
5 Cabinet Installation 9
5-1 Preparation 9
5-2 Unpacking 9
5-3 Placement 10
6 Wiring 11
6-1 Wiring Warnings 11
6-2 Wiring Preparation 11
6-3 UPS System Terminal Block Diagram 12
6-4 External Battery Cabinet Wiring Diagrams 12
6-5 Electrical and Cable Data 13
6-6 External Battery Cabinet Wiring 14
6-7 AC Input/Output Wiring (Single UPS—SUS) 14
6-8 AC Input/Output Wiring (Parallel Configuration—2x MUS) 15
6-9 AC Input/Output Wiring (Parallel Configuration—4x MUS) 16
7 Operating Modes 17
7-1 Online (Normal) Mode (Single UPS—SUS) 17
7-2 Battery Backup Mode (Single UPS—SUS) 17
7-3 Auto Bypass Mode (Single UPS—SUS) 17
7-4 Manual Bypass Mode (Single UPS—SUS) 17
7-5 On-line (Normal) Mode (Parallel UPS—MUS) 18
7-6 Battery Backup Mode (Parallel UPS—MUS) 18
7-7 Auto Bypass Mode (Parallel UPS—MUS) 18
7-8 Manual Bypass Mode (Parallel UPS—MUS) 19
7-9 External Maintenance Bypass (Parallel UPS—MUS) 19
8 Start-Up, Shutdown and Bypass 20
8-1 Control Panel and Breaker Diagrams 20
8-2 Preliminary Checklist (Single UPS—SUS) 20
8-3 Standard Start-Up Procedure (Single UPS—SUS) 21
8-4 Battery Start-Up Procedure (Single UPS—SUS) 22
8-5 Manual Bypass Procedure (Single UPS—SUS) 22
8-6 Shutdown Procedure (Single UPS—SUS) 24
8-7 Preliminary Checklist (Parallel UPS—MUS) 24
8-8 Start-Up Procedure (Parallel UPS—MUS) 25
8-9 Shutdown Procedure (Parallel UPS—MUS) 26
8-10 Switching to Manual Bypass Mode from Normal Mode
(Parallel UPS—MUS) 27
8-11 Switching to Normal Mode from Manual Bypass Mode
(Parallel UPS—MUS) 28
9 Power Module Status and Replacement 29
9-1 Power Module Features and Status 29
9-2 Preliminary Replacement Checklist 29
9-3 Replacement Procedure 29
10 Display and Configuration 30
10-1 Control Panel Diagram 30
10-2 Display Hierarchy 30
10-3 Default Display 31
10-3-1 Status Display 31
10-4 Main Menu 34
10-5 UPS Setup 36
10-5-1 Bypass Setup 37
10-5-2 Output Setup 38
10-5-3 Battery Setup 40
10-5-4 Charger Setup 43
10-5-5 Parallel Setup 44
10-5-6 Control & Test Setup 45
10-5-7 Local Setup 47
10-6 Maintenance 50
11 Communications 52
11-1 Communications Interfaces 52
11-2 SNMPWEBCARD Slot 52
11-3 Input Dry Contact Interface 52
11-4 Remote Emergency Power Off (EPO) Circuit Diagram 53
11-5 Auxiliary Dry Contact Input Circuit Diagram 53
11-6 External Battery Cabinet Temperature Inputs 53
11-7 External Battery Status Input 53
11-8 Output Dry Contact Interface Detail 54
11-9 Output Dry Contact Circuit Diagram 55
11-10 RS-232 Serial Port Circuit Diagram 55
11-11 Parallel Configuration Port 55
12 Specifications 56
12-1 UPS System Technical Specifications 56
12-2 UPS System Floor Loading Table 56
13 Storage and Service 57
14 Warranty 58
Español 59
Français 117
Русский 175
12-212-93-3141.indb 2 12/28/2012 11:16:51 AM