62 Zebra S-Series User’s Guide
/RZHU7UDQVPLVVLYH0HGLD6HQVRU3RVLWLRQ$GMXVWPHQW
To adjust the lower media sensor, follow these steps:
1. Locate the lower media sensor assembly (a spring clip holding a small
printed circuit board) under the rear idler roller.
2. Position the sensor so that the two brass-colored infrared emitters are
under the upper sensor by sliding it in its slot.
3. Gently pull wires out of the printer frame as required. (Wires should
have a little slack.)
Note: If the sensor is being moved inward and a large loop of wire
develops, remove the cover from the electronics side of the
printer and gently pull the wires through. It is important that the
wires be properly clamped so that they are not rubbed by any
belts.
Figure 25