Zebra Technologies S-300 Printer User Manual


 
MODE Key Self Test
This self test places the printer in a
Communications Diagnostics Mode. In this mode,
the printer prints the ASCII characters and their
corresponding hexadecimal values for any data
received from the host computer. See Figure 30.
Note: Turn the power OFF to exit this self test.
FEED Key and PAUSE Key
If it is ever necessary to reset the printer
configuration to the factory default values, press
these two keys at the same time while turning the
Power ON. Permanently save these values in
memory by pressing the MODE key four (4)
times - MODE lights cycle ON then OFF. A Media
Calibration procedure must be performed any time Factory Default values are
saved. See Chapter 1.
Extended Printer Diagnostics
Extended diagnostic tests are available for the Zebra Stripe Printer. The Stripe
Maintenance Manual, Volume 1 (part # 44868L), provides information needed to
perform these additional tests.
Figure 30 MODE Key Self Test Printout
Troubleshooting and Diagnostics
44