Zebra Technologies S4M Printer User Manual


 
47
Operations
Position the Media Sensors
10/21/05 S4M User Guide 13290L-001 Rev. A
Position the Media Sensors
This printer uses two types of media sensors: transmissive and reflective.
Select the Transmissive Sensor
The standard transmissive sensor (Figure 21) is in a fixed position and enabled from the
control panel. For more information about the operation of this sensor, see Select the Media
Sensor on page 62.
Figure 21 • Transmissive Sensor
Adjust the Reflective Sensor
The reflective sensor is compatible with most types of media. With non-continuous media, the
reflective sensor detects the start-of-label indicator (the notch, hole, black mark, or gap
between die-cut labels). With both continuous media and non-continuous media, the sensor
detects an out-of-paper condition. If you have difficulties with calibration while using this
sensor, use the transmissive sensor (see Select the Transmissive Sensor on page 47).
Position the reflective sensor in the following way:
directly under the notch, hole, or black mark with these types of labels
anywhere along the width of the media if there is a gap between labels
anywhere under the media for continuous media
The glow of the red light through the media may help you accurately position the sensor.
1
Standard transmissive sensor
1