Configuration
Control Panel LCD Display
10/21/05 S4M User Guide 13290L-001 Rev. A
ZPL OVERRIDE
(ZPL mode only)
Override Certain ZPL Commands
Prevents the printer from accepting the following ZPL commands:
^MM (media mode)
^MT (media type direct thermal or thermal transfer)
^MN (media non-continuous or continuous)
Selections:
NO—allows the printer to accept the listed ZPL commands.
YES—tells the printer to ignore the listed ZPL commands.
Default Value: NO
To modify this parameter:
Press the up or down arrow to scroll through the selections.
EPL OVERRIDE
(EPL mode only)
Override Certain EPL Commands
Prevents the printer from accepting certain EPL commands.
Selections:
DISABLED—allows the printer to accept the listed EPL commands.
ENABLED—tells the printer to ignore the listed EPL commands.
Default Value: DISABLED
To modify this parameter:
Press the up or down arrow to scroll through the selections.
SENSOR PROFILE
Print Sensor Profile
Use the sensor profile (Figure 26) to troubleshoot registration problems
that may occur if the media sensor detects preprinted areas on the media or
if it experiences difficulty in determining web location. To adjust the
sensitivity of the media and/or ribbon sensors, use Calibrate Media and
Ribbon Sensors on page 72.
Note • The ribbon portion of the label appears only for printers
that have the Thermal Transfer option installed.
Figure 26 • Sensor Profile
To select this parameter:
1. Press ENTER to start this standard calibration procedure and print a
media sensor profile.
Table 11 • Printer Parameters, Level 3 (Page 7 of 9)