Zebra Technologies Z4M Printer User Manual


 
74 Zebra Z4M/Z6M Printers User’s Guide
$ODEHOIRUPDWZDVVHQWWRWKHSULQWHU6HYHUDOODEHOVSULQWWKHQWKH
SULQWHUVNLSVPLVSODFHVPLVVHVRUGLVWRUWVWKHLPDJHRQWKHODEHO
$ODEHOIRUPDWZDVVHQWWRWKHSULQWHUEXWQRWUHFRJQL]HG7KH'$7$OLJKW
IODVKHVEXWQRSULQWLQJRFFXUV
Problem Solution
The host is set to EPP parallel
communications.
Change the settings on the computer host to standard
parallel communications.
The serial communication settings are
incorrect.
Standard RS-232 cables are appropriate for lengths under
50 feet; RS-422 and RS-485 cables allow serial
transmission up to 4000 feet. Check cable length and
shielding, and confirm the appropriate RS-232, RS-422, or
RS-485 setting is being used.
Check the printer driver or software communications
settings (if applicable).
Problem Solution
The prefix and delimiter characters set in the
printer do not match the ones in the label
format.
Verify the prefix and delimiter characters. See page 49.
Incorrect data is being sent to the printer. Check the communication settings on the computer. Ensure
that they match the printer settings.