EES-1024AF Intelligent Ethernet Switch
General Setup Using the SMT 5-1
This chapter shows you basic configuration using the SMT.
5.1 Ethernet Port Settings
Ethernet port connections can be in half-duplex or full-duplex mode. The Ethernet port must use the same speed or
duplex mode setting as the peer Ethernet port in order to connect.
Enter 2 from the main menu, and then type in the port number to bring up the Port Settings menu for the specified
port.
Figure 5-1 SMT - Port Settings
At the prompt, type the corresponding numerical numbers to configure. The Port Settings fields are explained in
the table below.
Table 5-1 Port Settings Fields
# FIELD DESCRIPTION EXAMPLE
0.1 Link This read-only field indicates the connection status of the port. Up
0.2 Speed/Duplex This read-only field shows the actual speed and the duplex mode of the
port.
100/FULL
1 Port Enabled Select this option to enable or disable the port. Enabled
2 Speed/Duplex Set the port speed and duplex mode with this option. The switch will auto
detect the speed and duplex mode of the attached device if you select
Auto; otherwise check the settings of the device attached to this port and
select from the following: 100/Full, 100/Half, 10/Full, and 10/Half.
Auto
3 Flow Control When this option is enabled, the switch sends a PAUSE message to the
device to pause the transmission when the buffer in the switch is full. This
works only for devices in full-duplex mode.
Enable
4 Back Pressure When this option is enabled, the switch sends a Back Pressure message to
the device to pause the transmission when the buffer in the switch is full.
This works only for devices in half-duplex mode.
Enable
Chapter 5
General
Setup Using the SMT
[Main] [Ports Settings]
module: 0, port: 1
0.1 Link (RO): Up
0.2 Speed/Duplex (RO): 100/Full
1. Port Enabled: Enabled
2. Speed/Duplex: Auto
3. Flow Control: Enabled
4. Back Pressure: Enabled
5. VLAN Tagged: No
6. Default VLAN ID: 1
7. Note:
Q. Quit
Select one function (1-7, Q):