ZyWALL 2 Series User’s Guide
23-12 WAN and Dial Backup Setup
Figure 23-8 Menu 11.4: Remote Node Script
The following table describes the fields in this menu.
Table 23-7 Menu 11.4: Remote Node Script
FIELD DESCRIPTION EXAMPLE
Active
Press [SPACE BAR] and then [ENTER] to select either Yes to enable the
AT strings or No to disable them.
No
(default)
Set 1-6:
Expect
Enter an Expect string to match. After matching the Expect string, the
ZyWALL returns the string in the Send field.
Set 1-6:
Send
Enter a string to send out after the Expect string is matched. 0.0.0.0
23.9 Remote Node Filter
Move the cursor to the field Edit Filter Sets in menu 11.1, and then press [SPACE BAR] to set the value to
Yes. Press [ENTER] to open Menu 11.5 - Remote Node Filter.
Use menu 11.5 to specify the filter set(s) to apply to the incoming and outgoing traffic between this remote
node and the ZyWALL to prevent certain packets from triggering calls. You can specify up to four filter sets
separated by commas, for example, 1, 5, 9, 12, in each filter field. Note that spaces are accepted in this field.
Please refer to the Filters chapter for more information on defining the filters.
Menu 11.4 - Remote Node Script
Active= No
Set 1: Set 5:
Expect= Expect=
Send= Send=
Set 2: Set 6:
Expect= Expect=
Send= Send=
Set 3:
Expect=
Send=
Set 4:
Expect=
Send=
Enter here to CONFIRM or ESC to CANCEL: